The above information is easily accessible and vital to the proper setup of the Ecobee system. Select Aux Heat Simultaneous Operation; select Enable. its 10 degrees out and the hp is struggling to heat the house. Using Kolmogorov complexity to measure difficulty of problems? We and our partners use cookies to Store and/or access information on a device. On the thermostat screen, navigate to main menu > settings > installation settings > thresholds depending on how your ecobee is configured, the thresholds you can adjust to reduce aux heat usage will differ depending on whether the configure staging threshold is set to automatically or manually. And not supplemental heat mode i do see that both the Ecobee3 and Ecobee3 lite are showing dual support. Welcome to my blog about Ecobee Settings Simultaneous Operation Of Auxiliary Heat Pump, where I explore the fascinating world of Ecobee Settings Simultaneous Operation Of Auxiliary Heat Pump and share my insights with you. I chose disable because it sounds safer. Page 7: Wiring Diagrams Diagram indicates 24V humidi er terminal. I have a Lennox unit and my ecobee4 asked me if I wanted to allow the heat pump and auxiliary to run simultaneously? Read on for everything you need to know about the EMS smart thermostat or download the installation guide and wiring diagrams as a PDF. If there are any programs or schedules in place, they will all be removed. The hot air from the furnace would be entering the heat pump's indoor coil, causing it to get too hot and then the heat pump will shut down due to high pressure. Wire it so that its common goes to the Ecobee W2 output, the normally closed terminal goes to the furnace W2 input, and the normally open terminal goes to the hydronic system. Heat pump and heat strips on simultaneously? - HVAC-Talk: Heating, Air What Does Aux Heat Mean? But it turns on automatically, which can be frustrating if you don't want it on. This system brings a wonderfully simple user interface to the heating system that homeowners will absolutely love. You can change the minimum run time to whatever you wish to save on electricity or oil bills. we have heat-pumps with electric strips as an auxiliary and they work a bit differently than a conventional furnace. When the temperature drops below 20 degrees, the heat pump will start to use auxiliary heat to maintain a comfortable indoor temperature. Single-stage heating systems allow for two functions to be controlled by the thermostat: heating and cooling. Then go to Settings > Installation Settings > Thresholds > Compressor to Aux Runtime. It defaults to using a heat pump to heat your home without using much electricity. But there is a limit, and systems (in general, not just heat pumps and HVAC) are designed to handle 95% or 98% or something like that, so there will be occasional days that it just gets too cold for it work. You have the option to turn off the aux heat alerts, though it is nice to see why and when your heating bill fluctuates. Recently, we've installed a heatpump with electric auxiliary heat. 2 Ways To Fix Ecobee Auxiliary Heat Running Too Long This article will explain heat pumps and how thermostats operate them. If your heat pump is using auxiliary heat, it means that the ambient temperature outside is too cold for the heat pump to work efficiently. Ensure that your Aux runtime is set to the right amount as well. You can reset it by following these steps: Now lets see what each of the three reset options is for. All rights reserved. "heat blowing cold air" is my main issue indeed. Ecobee also offers the benefit of customization to users that pair the smart device with an air-to-air heat pump in an effort to use less energy and save more money on their monthly bills and expenses. This will cut power to your furnace and thermostat too. . I look forward to hearing your feedback and ideas, and I'm excited to embark on this journey of discovery with you. To set ecobee up for a geothermal or air-to-heat pump, take the following steps: Determine how to energize the pump reverse valve Figure out if the heat pump and auxiliary heat need to run at the same time Ensure that ecobee is compatible with the heating system you have In this article, we have explained the 2 ways on how you can fix Ecobee auxiliary heat running too long. This feature heats your home faster than a heat pump can. (What to do), 3 Best HVAC Companies in Owens Cross Roads, AL, Why Wouldnt a Mini-Split Be Heating? That also gives you the option that if you have a power outage and an appropriately installed, but relatively small, generator, you can run the oil heat, because it won't need nearly as much electricity as the heat pump and the electric aux. Change the minimum compressor outdoor temperature threshold but only if your equipment can run safely at a lower temperature. 01:05 why is my auxiliary. This erases all schedules, programs, and preferences back to the default setting. that is how I have things wired - but in the config - electric aux heat does not get engaged, as the ecobee can't seem to handle powering up both aux heat, and oil heat. because it is "good enough" or because you are running low on oil - just flip the switch! I can change it to none but we do generally get a few nights a year below -10 and record lows are into the -20s. A Simple Way to Calculate Heat Pump Balance Point Increase the value so the auxiliary heat takes longer to kick on. Open the furnace door to check on the control board panel. Do you want to reset your Ecobee thermostat, but you dont have the access code? Because the Ecobee is powered by the forced air furnace while the hydronic system has its own separate 24 volt transformer, you'll have to either arrange things so that the two transformers are in phase or else use a relay to interface with the hydronic system. Thank you for visiting, and let's explore the wonders of Ecobee Settings Simultaneous Operation Of Auxiliary Heat Pump together! Find out how long the Auxiliary Heat should run and what to do if it doesnt shut off. This will drastically lower the use of auxiliary heat which should be ideal for you. Should Heat Pump Run While on Auxiliary Heat? 3. Start at the web portal. heat pumps: air, water, and geothermal with up to 2 stages, and 2 stages of aux heat. (but not simultaneously of course). Will A Gas Furnace Work Without Electricity? If you are also one of these users, then you have nothing to worry about. I'm omitting a wiring diagram in hopes that you'll be able to work out that part on your own. Auxiliary heat turns on automatically, taking over for the main heat pump when it can no longer sufficiently warm the house quickly enough. The Ecobee thermostat is able to run a single-stage heat pump and a second-stage one as well. Aux heat systems can be oil-based heating units, natural gas furnaces, or electric resistance systems. If you choose not to engage this option, your heat pump runs for 2 hours before switching to the auxiliary heat if the setpoint isnt met. Click on the icon on top of the temperature reading on your thermostat. The incredibly versatile Ecobee thermostat is more than capable of running the functions of both single-stage and second-stage heat pumps. very cold - oil heat (stage 2 aux). if aux heat is a furnace, the aux and heat pump should not run simultaneously. 3. heat, I would just wire up the oil heat to stage 2 and be done. Ecobee recommended settings for Heat Pumps : r/ecobee - reddit heat pump thermostat programming to save you money diy ecobee smart thermostat nest honeywell tips and tricks to a client recently booked an appointment with us for this reason: "i received an alert for my thermostat stating that my heat pump is 00:00 is it bad if auxiliary heat comes on? Chromecast Audio is an excellent device for streaming music or audio from your phone or computer to your home speakers. When wiring the the older system to RH, W2 on the ecobee - the electric (new) aux heat - does not engage anymore. This can be a great way to make sure that your home is heated evenly and efficiently, without running the risk of overworking your system. An example of data being processed may be a unique identifier stored in a cookie. I have had this heat pump for three years, and I am yet to have any issues with its performance. Two stage heat pump with or without AUX heat : Two stage heat pump with separate two stage furnace heating (Dual fuel) 1, 2 : Humidifier* or dehumidifier 1, 2 : . If your system is running in Auxiliary Heat mode for extended periods of time, there may be an issue that needs to be addressed. How to minimize the use of auxiliary heat with a heat-pump on - ecobee This could be the reason your thermostat is not turning on. The ideal temperature for a heat pump to operate is between 20 and 30 degrees Fahrenheit. Make sure the threshold isnt set to too high or too low. DIYSmartHomeHub.com is a participant of the Amazon Services LLC Associates Program, an affiliate advertising program it is designed to provide an aid for the websites in earning an advertisement fee by means of advertising and linking to Amazon.com products. The ecobee Smart Thermostat uses a unique method for staging fo r multi-stage heating or cooling. Im assuming Fahrenheit obviously, the heat pump will always be more efficient if slower. rev2023.3.3.43278. A heat pump system with an auxiliary heat option is your best bet for emergency heat. It acts as a secondary heat source and helps you heat your room quickly. Auxiliary heat and emergency heat are two different things. This site also participates in other affiliate programs and is compensated for referring traffic and business to these companies at no additional cost to you. Auxiliary heat refers to your heat pump's backup electric resistance heating. This reverts your thermostat back to its factory setting. Ecobee recommends you set your auxiliary savings to Super (2F / 1.1C). so a 3 score is saying average and it is. I would have been happy to do away with the old, but the forced air - ins't cutting it. The display panel has been the most significant cost in manufacturing a conventional TV. Ecobee Settings Simultaneous Operation Of Auxiliary Heat Pump . When the auxiliary heat is on, youll notice that your air conditioners fan will continue to run, but the compressor will be off. With this arrangement when the Ecobee decides stage 2 heat is needed the relay will control whether that stage 2 calls goes to the resistance heat OR to the hydronic heat. The Ecobee will allow the user to declare customized preferences to ensure that their home is heated to their desired temperature in an efficient way. If you have an ecobee3 thermostat, you know that it can be tricky to keep your home comfortable while also being energy efficient. You can also set it to automatically determine when it should use the auxiliary heat. How To Set Ecobee Thermostat To Emergency Heat - HVACseer.com So when temperatures drop and your heat pump cant keep up, both systems will run together until things warm back up again. The alert from Ecobee simply lets you know your more expensive heat system has been running for a while. On the thermostat screen navigate to main menu gt settings gt installation settings gt thresholds depending on how your ecobee is configured the thresholds you can adjust to reduce aux heat usage will differ depending on whether the configure staging threshold is set to automatically or manually-, Ecobee Settings Simultaneous Operation Of Auxiliary Heat Pump Youtube. but that's not a real solution as during a week, this may need to be done a few times. I dont have gas and Im in south Louisiana where it doesnt get crazy cold, if that helps? This prevents the aux heat from running past a certain outdoor temperature. This is how the RiteTemp is actually hooked up. Still, Ecobee can be used with this technology without any problems whatsoever. Ecobee is a well-known Canadian home automation company, particularly famous for its thermostats. Press J to jump to the feed. You can find the Threshold settings by going to Settings > Installation Settings. hmm, in terms of wiring, which would go into w1, and w2 in this scenario ? ecobee Settings: Simultaneous Operation of Auxiliary + Heat Pump, Ecobee Allow Heat Pump And Aux Heat to Run Simultaneously. The Ecobee is up to the task of running a single-stage heat pump with no problems whatsoever from start to finish. Should Heat Pump And Furnace Be Running at the Same Time? While heat pumps are not all too rare, they are used far less than other heating systems. 2. You will need to reprogram all personal information and settings after choosing this option. link to How Much Does It Cost To Make a Smart TV? Ecobee is a more user-friendly control system for a person to connect with their utilities. That temperature varies by system and has been improving. Brand & Model & Size Price Home Location Home Size. This 'COMP TO AUX DELTA' option now asks for the indoor temperature to drop by how many degrees before using the auxiliary heat. Going to MENU > SETTINGS > INSTALLATION SETTINGS > THRESHOLDS > COMP TO AUX DELTA can help you do this. If your heat pump is running while on auxiliary heat, it may be an indication that something is wrong with your system. Meaning, your aux heat will run for a period of five minutes before shutting off. The problem: actually the answer is "yes", to the above. A second-stage heat pump will fluctuate between a high intensity and a low intensity of heat to achieve a steady temperature in the home. By running both at the same time, you can ensure that your home is being heated efficiently. Why is there a voltage on my HDMI and coaxial cables? To do that firstly, you need to be sure of what type of system you have. Step 2: Wire the Equipment Interface. Sure, There are always corner cases. If your Ecobee is not turning off the heat when the set temperature is reached, then a bad thermostat wiring could be the reason for this problem.