Start with turning off the gas control valve to the off position. Not only that, but it also causes the Pentair pool heater to turn off. Turn off the main connection and clean all the airflow, water, and gas pipes properly. So, keep reading. ], Bosch Tankless Water Heater Maintenance [The Complete Guide], Bosch Tankless Water Heater Troubleshooting [A Complete Guide], Bosch Tankless Water Heater Error Codes [Ultimate Guide], Bosch Tankless Water Heater Wont Ignite [7 Easy Solutions]. Either the thermopile doesnt cool down quickly or the pilot valve is stuck in an open position. Problem: Problem with the air-fuel ratio rod - AFR. Solution: Check for connection and wire breakage or computer board failure (burn marks). Error code E02 on AO Smith Electric Tankless Water Heater indicates that the unit determines the heated water exceeds the temperature limit. Remove the access panel and fold away the insulation. It may stay that way for a few hours but eventually the heater shuts off and the light flashes red (2 times) again. Whether you have a newly installed AO Smith Gas water heater or an older one, you must light up the pilot first. Smith Water Heater, look no further! how to fix the Pentair heater error codes problem, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. Gas water heater using too much gas. Solution: Check for the proper settings on the computer board. Legal Disclosure:Lildutchuncle.com provides and shares information on plumbing, heating & air quality, home improvement, and other DIY projects. If the remote controller is not installed on the water heater, and there is a problem, the error codes will be shown differently. Now, wait for 10 minutes to let the thermopile cool down. Also, you should check the computer board for any sign of burn marks too. Our comprehensive A.O. I dont recommend you perform this workflow by yourself. This error code occurs when there is a problem with the inlet thermistor. Solution: Check if the Hi-limit switch properly functions and that there is no loose or broken wire connections, no soot on the flame rod, or a damaged computer board. Find the most common problems and see how to fix issues. Solution: See the error codes 331, 321, and 311. Its very simple to reset your AO Smith Electric Water Heater by following the below instructions: ECC stands for Electro-chemical compression. Put everything back into its place and turn the electricity on. smith gas water heater installation user and service manual (102 pages) Water Heater A.O.Smith GPSX-50L Owner's Manual. Manage Settings These cookies ensure basic functionalities and security features of the website, anonymously. If this error code has appeared on your AO Smith tankless water heaters LED screen, then this is a sign that you have set the incorrect settings for the dipswitch. GPVH50100 GPVH50101 XCVL40-200. })(); Anthony Barnes is the founder of Water Heater Hub and a second-generation plumber by profession. Then, disconnect the thermistor and reconnect it. Alternatively, you can watch this video that will come in handy: AO Smith Water Heater Status Light will flash 8 times every 3 seconds if the gas control valve is in the off position but the thermopile still produces electric power. Problem: Warning for the "991" error code. If you own a 540 model AO Smith tankless water heater, then this is an error code that may appear on your display screen. Of course, you are always open to reaching out to a professional if you fail to clear the error messages. Smith Water Heater Manuals Anthony Barnes July 23, 2018 Need to Hire a Plumber? They have to make sure that it can function properly. Your AO Smith Water Heater will flash the error code E03 if there is a low water level in the heater. Problem: Gas solenoid valve drive circuit failure. However, I highly recommend you call a certified plumber to solve this issue. AO Smith water heaters are designed to last. This thermistor should be found attached to your water heaters exhaust. Hotwatertalk.com is a participant in the Amazon Services LLC Associates Program and other affiliate advertising programs, designed to provide a means for us to earn fees by linking to the affiliated sites. Look for the blockage in the vent system and ensure if the distance between the intake and exhaust is not too small. Than ks anyway Appliance Technician: Chester Just ignore the pop-up call request. Afterward, install a new thermistor. Solution: Check if the condensate drain is installed on the vent collar of the heater. . This time, it is referring to a problem with your exhaust thermistor. Once you solve the leak issue, return the electric power to your water heater. The cause of this problem could be a range of different issues including connection issues, broken wires, and even corrosion around the connectors. I replaced it with another AO Smith model, but a more base model without the smart module option. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. Is Spray Paint Flammable? An example of data being processed may be a unique identifier stored in a cookie. Though the brand is different, it will help you a lot in finding the leaking point. Products: Water Heaters . Problem: Problem with the computer board. These cookies will be stored in your browser only with your consent. The solution for this problem is by checking the Hi-limit switch. AO Smith electric water heater keeps shutting off, e02 mike4500 Jun 18, 2019 M mike4500 Premium Member Joined Jun 18, 2019 Messages 5 Location NJ Jun 18, 2019 #1 Model Number 50 g Brand -brand- Age 1-5 years I have an AO Smith 50 gallon with the electronic display. Error code 510 (LED flashes six times) Problem: Gas solenoid valve malfunction. Bathtub faucets typically have a flow rate of 5 Gallons per Minute. Scale is caused by water settling on heat transfer surfaces and the impurities build up into a hard, crusty layer. Dirty/Blocked Filter How To Reset AO Smith Water Heater Easily FAQs: What are the common problems of the AO Smith water heater? How do I reset my A.O. Smith water heater? Finally, turn the power back to the unit and it will clear the error code. Use the AO Smith code guide to find the main causes and solutions for the problems of the following models: 110, 310, 510, 240, 340, and 540 series, for safety, convenience, and great savings. GCV40-200 GCV40-201 GCV50-200 GCV50-201 GCVH40L-200 GCVH40L-201. This error code signifies that there is a problem with your outlet thermistor. The showers in homes built after 1992 typically have a flow rate of 2.1 Gallons Per Minute. FIX: Check if the condensate drain is installed on the vent collar of the heater. And this will reset the water heater successfully. If needed, adjust the thermostat setting. A.O. Now, press the red button to reset the unit successfully. As a result, you can now easily diagnose your water heater that will save you both time and money. Error Code 61, 611, Four times Problem: Fan motor fault. So, its worth bookmarking this article. Models from the 240, 340, and 540 series will show the error codes on both temperature controller and remote controller. This is usually caused by scale build up which locks the motor drive. You dont need to take any corrective actions as the status light of a functioning unit blinks 1 time every 3 seconds. Next, use the -inch open-end wrench and pull out the thermistor by turning it counter-clockwise. ); Second, the thermopile of your gas water heater has not reached its operating temperature yet. But then sometime later it will start to heat the water and the green light will begin flashing rapidly. In the Pentair pool heater exchanger, the thermal regulator helps the water reach a certain temperature and heat up the pool water. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Many factors affect the actual performance of a water heater. event : evt, In contrast, 4 consecutive flashes with a 3-second pause indicates the temperature sensor of the unit senses the water temperature is too high. All Right Reserved by FIREPLACEHUBS. You are using an out of date browser. Finally, install the thermostat professionally if it doesnt fit against the tank snugly. Most of the time, this error occurs when there is a wire connection issue or a breakage, which can easily be fixed or replaced. Open the control panel and make sure that the stack flue sensor is working properly. We also use third-party cookies that help us analyze and understand how you use this website. AO Smith tankless water heaters equipped with the remote controller have a great advantage; a self-diagnosing function that helps in diagnosing the heating problem. Basically, both 2-chamber and 4-chamber models will pop up with those error codes. Wait for ten minutes to allow all the gas to clear out. Of course, there will be a solution which can be used for fixing this problem. Use the pipe wrench to tighten the fittings. What you need to do is- attach the thermistor wires to the control board. If the status light still doesnt come on, I bet the pilot flame fails to heat the thermopile sufficiently. Instruction Manual - High quality water heaters and water treatment . Smith water heater? While it may be igniting, its not keeping its flame and is going out before it can adequately warm up your water. Fixing the error as soon as it appears is important for the performance and longevity of the pool heater. Alternatively, you should check for any loose connections and damaged wires that could be behind this power loss. window.mc4wp.listeners.push( Any other models may have different codes for different issues. Break down what troubleshooting steps you should take to stop the blinking lights. This represents our closest approximation of your likely experience with this water heater using National Averages, but actual performance may vary depending on factors beyond our ability
The work of the stack flue sensor is to detect the exhaust temperature of the heater and make sure that it does not exceed 176 degrees Celsius. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. A Appliance Helpers representative is available for you 7 days-a-week including Holidays!! Turn the gas supply off at the manual shut-off valve on the gas supply line. Yes, the heater heater light should blink as the flashing light will help you to understand whether the heater is working properly or not. Eric Alvarez is an HVAC guy based in El Paso, Texas, United States. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. Where this thermistor is will vary from model to model, so you will need to check your manual to find it on your water heater. This is the error code for ignition failure. Read also : Noritz Error Code Troubleshooting. The AO Smith water heater is too hot. Smith INTELLI-VENT Page 1 INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters Printed in the USA - 0605 Part No. Regarding this, you need to replace the thermocouple or the wire connectors. The consent submitted will only be used for data processing originating from this website. Just turn on a hot water faucet and let the water run for several minutes. Alternatively, the error code will flash four times. AO Smith Water Heater Troubleshooting Lights [8 Common Blinking Light Codes]. To solve this problem, you will need to find the correct settings for your water heaters model and reset them on the computer board. Next, check for water leaks and fix them if needed.
They should also remove the grease or dirt which can be found in the fan motor as well as the gas burner. Then, hand-tighten the thermistor first. Though we share resources, information, and educational guide on plumbing & DIY projects, the content here is not a substitute for professional guidance. Leak Watch Smart technologyimmediately alerts you of a leak for yourpeace of mind. But opting out of some of these cookies may affect your browsing experience. CODE: 99, 991, Five timesPROBLEM: Improper gas combustion. Fold away the insulation to access the reset button (its red). Alarm reads E05 and a lot of water is going thru the overflow drain pipe It's still under warranty. People only need to check for the right setting on the computer board of the water heater. This is the final error code for thermistor failure. If the condensate drain is not properly installed on the vent collar of the water heater, then there could be water in the internal combustion engine. Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors. Leak Shield shut off valve automatically shuts off watersupply when a leak is detected (accessoryincluded). Get information and support for all A. O. Smith models. I They should be able to tell you the correct dipswitch settings for your model so you can correct it yourself. For example, if the status light blinks 2 times, there is an issue with the thermopile voltage output. Continue with Recommended Cookies. More error codes can be found after all. This website uses cookies to improve your experience while you navigate through the website. I turned off for 5 minutes then back on. FREE Estimates! And the reason is the thermistor gets shorted electrically. FIX: Check for blockage in the vents, the distance between the intake and exhaust terminals are per instructions and remove if there is grease or dirt in the gas burner and fan motor. It is a 50 gallon A O Smith just installed in new home 6 months ago.LG12-50R55DV 210. Turns out, ensure you dont set the thermostat too high. Fortunately, I broke down how you can replace the thermistor correctly in this section: Ao Smith Electric Water Heater Error Code E10-E13. Takagi Water Heater Error Codes [Ultimate Guide], AO Smith Electric Water Heater Troubleshooting, AO Smith Water Heater Troubleshooting Codes, AO Smith Gas Water Heater Troubleshooting, 9 AO Smith Gas Water Heater Troubleshooting Tips, AO Smith Water Heater Not Heating [5 Easy Solutions], Bosch Tankless Water Heater Maintenance [The Complete Guide], Bosch Tankless Water Heater Troubleshooting [A Complete Guide], Bosch Tankless Water Heater Error Codes [Ultimate Guide]. The thermostat(s) on this water heater have been factory set to 120F to reduce the risk of scald injury. Solution: Is the water heater set for the right elevation? To fix this issue, you should replace this part. I hav been reading some similar posts regarding this issue, and I think I have made the proper analysis. AO Smith Water Heater will throw an error code or make a beeping noise if the unit is not working properly. FIX: Debris on the thermistor, loose or broken wire connection. Here are some error codes which can be learned. What I will break down on this in-depth guide on AO Smith Water Heater Troubleshooting Lights: It depends on how many times the flashing light is blinking. Here is the answer. The water heater is surely essential to support modern households, and we can make sure that people will look for the best water heater which can be used for their household needs. Built in dry fire protection will not allow the water heater to be turned on unless the tank is full of water, eliminating accidentally burning out the upper element. If you have either a 2-chamber or 4-chamber model of AO Smith Water Heater, you can see the trouble codes E20, E21, E22, E23, and E24 for a single reason. Fix the loose wiring and replace the damaged wires. ao smith water heater error code e05. Keep in mind that the error codes are shown differently if the units are connected through the Easy-Link System it can be seen what the error code is and which unit has it. You can either left-click on the link to open the manual in a new tab or right-click and save a copy directly on your computer. Related Error Code Pages:A.O. Revision 2 includes updated troubleshooting information for error codes 3, 4, and 6. Find the right water treatment products for your needs. Like other heat pump water heaters, AO Smith Heat Pump Water Heater uses the ECC or transformative solid state technology to reduce the energy usage. Smith maintains its leading position in the market. COPYRIGHT 2023. Analytical cookies are used to understand how visitors interact with the website. Detach the thermistor and reattach it again. Your AO Smith Water Heater will make a beep once it detects a problem to notify you that something is going wrong with the unit. 4.6. Get a free estimate online from top local home service pros in your area. Eccotemp Protection Plans are available for purchase within 60 days of your water heater purchase. So, check the previous chapter again. 50 Gallon Tall 12-Year Energy Smart 5500/5500-Watt Elements Electric Water Heater with Leak Detection Model: EE12-50H55DVF Lowe's Item #: 3806368 Shop Now at Lowe's Product Description iCOMM Smart Connectivity allows you to get notifications and manage your water heater from your smartphone How to use a diagnostic system to repair a faulty heater. A.O. Find the right water heater for your needs. Premium 5500 Watt Stainless Steel Heating Elements are more efficient and longer lasting than conventional elements, with higher recovery. FIX: Check is the Hi-limit switch properly functioning that there is no loose or broken wire connections, no soot on the flame rod or damaged computer board. Now, relight the pilot light by following the step-by-step guide I mentioned earlier in this article. Necessary cookies are absolutely essential for the website to function properly. Smith G9-T5040NVR Installation Instructions And Use & Care Manual. Note: You can also read how to fix the Pentair heater error codes problem. This is a popular problem that a lot of AO Smith tankless water heater owners suffer from because this error code usually occurs when there is an ignition failure. Some of the problems are common, and they do not include an error code: Water is not hot enough or is too hot The temperature of the exiting water fluctuates Noise Burner does not ignite Long time to get hot water Sediment buildup The fan activates after flow is detected. How To Fix: To fix this issue, you should replace the control board. Although the early symptoms are dizziness or a headache, death may be the final result if they cannot get the proper treatment. Disconnect every connection like the igniter wire, thermopile wire, pilot tube, and manifold tube from the gas control valve. Pentair heater error codes are ERR PS, ERR HLS, ERR AFS, ERR IGN, ERR AGS, ERR SFS, E01, E05, and E06. CODE: 39, 391, Two timesPROBLEM: Problem with the air-fuel ratio rod - AFR. But if you have to increase the water temperature, try to stay well below 150F (65C) so the high limit switch doesn't trip. A Pentair pool heater typically functions for 6 to 12 years on average. A list of Takagi error codes for easy troubleshooting of Takagi tankless water heaters. Smith University | An Education in Hotwater Register NOW for live online workshops! This prevents proper connectivity between the system and the sensor, causing the heater to shut down and display the E05 error code. Our comprehensive A.O. We are going to cover some of the most common error codes and problems seen with the AO Smith tankless water heater so you know what you can do when the issue occurs. This debris will be what is preventing your water heater from functioning properly. Tank. WaterHeater HUB 2021 - All Rights Reserved. Whats the average air temperature in the room where your water heater will be installed? You should keep depressing the igniter button for 90 seconds. Clean: Check the AFR rod for soot and clean it if necessary. The flame rod should be free from dirt and grease, and the computer board should not be damaged. However, a damaged thermal regulator often prevents the water from flowing out, causing it to be trapped in the exchanger. To solve this error, you will need to carry out the same checks and treatments in the above error. Copyright. Finally, turn on your water heater and you can see the error code is gone. Solution: Check the wire connection for looseness or breakage. Is there leaking from the heat exchanger? We will assume that the tankless unit, before failure, was correctly installed (with the correct gas type), per the manufacturer's instructions and codes. Problem: Bypass valve fault (only model 540). You also have the option to opt-out of these cookies. Smith water heater last? The Pentair heater e05 error code is one of the 12 error codes for this pool heater. CODE: 70, 701, One timePROBLEM: Problem with the computer board. Check for hidden leaks in hot water system . Clean the gas pipes properly if they are clogged and do not forget to turn off the valve before cleaning. To bring your water heater to a normal operating state, you should replace the temperature sensor. FIX: Check for connection and breakage of wires, burn marks on the computer board, and power supply to the unit. 13 February 2021; Non class; 0 Comments Then, find the source of the water leak. listeners: [], Through constant innovation, at production level and application level, A.O. The cookie is used to store the user consent for the cookies in the category "Other. The accumulated water will not allow the Pentair pool heater to work properly or shut off completely. The reason behind this is that the heater does not get enough water to heat up properly causing an imbalance in temperature. To solve this issue, there is no way except replacing the gas control valve. Does the status light of your AO Smith Water Heater remain solid red? 113 Flame On Should be Off Fail This is the thermistor attached to your outlet pipes. He has a good standing reputation for superior skills in heating, air conditioning, hot water tanks, and indoor air quality systems. } Brand: A.O. AO Smith Electric Water Heater Troubleshooting. This cookie is set by GDPR Cookie Consent plugin. Now, you should be able to understand how these error codes work and what they mean. Now there are quite a few reasons why this error code appears, including a faulty stack flue sensor, damaged thermal regulator, and improper gas pressure. To have the unit working properly, it has to be supplied with the power and correct connection. Common symptoms, problems, and fixing tips. They only need to check if there is any blockage in the vents. Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features. Ensure you shut off the electric supply to your water heater. Register now, spots are limited! Learn more, Facebook II Twitter II Pinterest II Linkedin. Residential & Commercial Water Heating Systems | A. O. Smith Never Descale Again. When the water leaks out of any place from the water heater, the leak sensor senses it and notifies you by throwing the fault code E04. Manage Settings You can do a few basic checks first like making sure there are no loose wire connections or soot on the flame rod. When the temperature sensor senses the water temperature is excessively hot, the status light will flash 4 times. If they come loose, tighten them up. FIX: Check the wire connection, wire breakage and debris on the flow sensor impeller. Sometimes if you are lucky, it could just be a bit of soot blocking the sensors other times, you may need to find a replacement AFR rod as soon as possible. CODE: 03 (031), One timePROBLEM: Incorrect dipswitch settings. FIX: Is the water heater set for the right elevation? CODE: 74, 741, 751PROBLEM: Miscommunication between the water heater and remote controller. ST. Manual for 300 models. Once your inlet thermistor is clean and properly connected, then the error code should vanish and your water heater return to its usual state. Smith with Intelli-vent device. Tank Guard gives you advanced tank protectionextends the life of your water heater. This chapter will discuss everything you need to know about the flashing light codes on AO Smith Water Heater. You can read this article on Rheem Water Heater Leaking. Dont need to worry about it. To determine if the heating element is shorted out, plug in a multimeter and test if the element, itself, is shorted. 2023 Virtual Campus Workshop Schedule Tour our upgraded studio and training facilities http://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.html#intellivent, When Used On Gas, Residential, Power Vented. Previous replacement, improper installation and other conditions, outside the manufacturer's control and requirements for warranty may prevent reimbursement. Smith - Troubleshooting help - Hello my frist post here. Examine the water pipes and make sure that they are clean. Solution: Connections or wire breakage of the flow adjustment valve, scale buildup on the motor drive that gets locked, or there is water leakage. Verify the O-ring is in its place. To bring your water heater to a normal operating state, you should replace the temperature sensor. Take out the thermal regulator and replace it with a new one. Besides, I will also walk you through the troubleshooting steps to clear those error messages. FIX: Check for connection/breakage of wires, corrosion or frozen connectors, fan motor covered with the dust, burn marks on the computer board. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. How long does an A.O. Hi, I have an AO Smith GCVL 40 300 natural gas with a Honeywell valve. How to tell if the AO smith water heater is working? Sometimes, a faulty sensor is also responsible for this issue. Should the water heater light be blinking? Its normal. Your AO Smith Electric Water Heater will throw the error codes E10, E11, E12, and E13 either for an open inlet temperature sensor or open thermistor. Jenn-Air JGS8750ADB Control Panel Burning Hot! Generally, the water heater will display this faulty code if the outlet thermistor (TH-4) remains open. These are The Easy Steps, The sound of the door squeaking is certainly very, You may want to remove broken drills from wood when, Spray paint is an aerosol paint that is used by, The toilet flange heightis important for proper, After you receive your new washing machine, you are, Most people take it for granted that their, Like most people, you probably take your air, Copyright 2022 Burnshomeconstruction.com. If there are any burn marks on the computer board then this is a sign that your water heaters computer board is overheating and cutting out. It will be far better if you call a certified technician to deal with this issue.